What’S Included:
- Expandable Manual Ranging Stick Multimeter For Hvac/R – Hs33
- 400A Amp Clamp Accessory – Ach4
- Deluxe Silicone Test Leads – Adls2
- Short Alligator Lead Extensions – Asa2
- Deluxe Meter Case – Anc1
- 9V Battery (Installed)
- Operator’S Manual
Based On The Success Of Our Original Stick Meter Line, (Hs26) The Hs33 Was Designed To Measure Even More Hvac/R Parameters Including Temperature With Quick Compensation Via A K-Type Thermocouple Plug, A Diode Test And A Built-In Non-Contact Voltage (Ncv) Tester. The Updated Ergonomic Shape Fits Firmly And Naturally In Your Hand While Testing. A Magnetic Hanger, Along With The Detachable Test Leads And Alligator Clip Probe Tips, Allow You To Remote Test And Perform Other Tests Hands-Free. This Is The Stick Meter Schools Prefer For Their Hvac/R Students. It’S Got All The Basics And More. The Rugged Rubberized Bumpers Help This Meter Stand Up To Tough Conditions In The Field. Ranges Include Vac, Vdc, Aac, Adc, Temperature, Capacitance (Mfd) And A Host Of Other Built-In Safety Features.
The Hs33 Is Unique In That It’S A Great “Starter” Meter For New Field Technicians As Well As A Top Performer For Veterans Who Prefer Manual Ranging Digital Multimeters Meters. All Fieldpiece Accessory Heads Slide On The Top, Enabling The User To Test A Wider Variety Of Parameters From A Single Meter. All This Plus The Removable Tip Test Leads Make Safe One-Handed Testing A Snap. As With All Electrical Testing, Please Read The Operator’S Manual And Associated Safety Practices Thoroughly Before Testing And Adhere To Industry Best Practices For Safety When Testing Any Current Carrying Device.
Features And Benefits:
The Hs Meter Series Is Unlike Any Other Found In Hvac/R. We Incorporate A Number Of Safety Features, Both Those You Can And Can’T See, Into Our Meters. In Addition, The Hs Series Accepts Modular Test Instrument Accessory Heads. The Hs33 Is The First Evolution Of The Stick Meter Concept. While The Function Of The Meter Is Similar To The Original Stick Meter Line, We’Ve Updated It Since Its Introduction To Include A Number Of Features That Make The Hvac/R Technicians Job Easier, Better And Safer.
Non-Contact Voltage
With The Red Ncv Tab On The Tip Of The Meter Close To An Ac Voltage, Press And Hold The Ncv Button. The Ncv Led Will Light With An Analog Feel And The Beeper Will Beep. The Closer You Get To Ac Voltage, The Louder The Beep. The Ncv Function Is Sensitive Enough To Detect 24Vac On Thermostats.
The Non-Contact Voltage Feature Can Be Used In Conjunction With One Probe Tip To Find Which Wire Is Live. With Meter Set To Off, Place Probe Tip In Red Plug As Shown Below. Hold Down Ncv While Touching Each Wire, A Noticeably Louder Buzz Will Sound When You’Ve Touched A Live Wire.
400Aac
Using The Included Amp Clamp Accessory, Model Ach4, On The 200 Mvac Range Allows You To Read 0-400 Amps Directly On Your Meter With 0.1 Resolution. Use It With The Detachable Test Leads To Remote The Amp Clamp And Test With The Blower Door Closed For More Accurate Readings.
Capacitance
For Motor-Start And Motor-Run Capacitors. Disconnect The Capacitor From Power First. Short The Terminals To Discharge The Capacitor. Disconnect Any Resistors That Might Be Between The Terminals Of The Capacitor.
High Voltage And Continuity Indicators
In Any Vac/Vdc Range, When You Touch A Voltage Greater Than 30V, The Beeper Will Beep And The Red Hi-V Led Will Signal You. Be Careful! The Continuity Beeper And Green Led Tell You If The Circuit You’Re Testing Is Open Or Closed.
Min/Max And Data Hold
Press Min/Max Once To Begin Recording Min And Max
Press Min/Max To Select Current Reading’S Min Or Max
Hold Down For 2 Seconds To Exit Min/Max Function. Press Hold To Hold Data
Silicone Leads With Detachable Probe Tips
Because The Wire Insulation Is Silicone The Leads Will Stay Flexible In Cold Weather And Will Not Melt If Bumped By A Soldering Iron. When Testing Electrical Circuits With Two Hands, There Is A Risk That A Careless Mistake May Complete A Circuit Through Your Body And Potentially Cause Death Or Injury. Detachable Probes Tips And The Modular Design Of The Hs33 Allow You To Plug V Lead Tip Into The Top Of The Meter, Connect An Alligator Lead Tip To Com And Ground, And Perform A One-Hand Test More Easily Than Most Any Meter On The Market.
More Features:
- Rugged Abs Case With Rubberized Bumpers
- Built-In Magnetic Hanger Allows You To Test With One Hand Or No-Hands
- Built-In Lead Storage
- Ergonomic Shape Fits Naturally In Your Hand
- Auto Power-Off (Apo) To Conserve Battery Life
It Wasn’T Too Long Ago That The Only Multimeter You Could Buy Was Designed For Lab Use. Today’S Hvac/R Technician Can Buy Meters With Functions And Features Specifically Designed For Field Use. And, They’Re More Rugged, Convenient, And Safe. Clips For One-Handed Testing. Loud Beepers And Bright Leds To Warn Of Dangerous Voltages, Even In Noisy Environments. Magnetic Hangers. Automatic Hold And Max So Eyes Stay Focused On The Test Point. Silicone Leads. Manual Ranging.Plus, Modular Expandability Allows You To Take A Truckload Of Test Instruments To The Job In A Bag Over Your Shoulder.
Additional Specifications:
Diode Test
Test Current: ~1.0Ma
Accuracy: ±(1.5% Rdg + 3 Dgts)
Open Circuit Volts: 3.0Vdc Typical
Overload Protection: 500Vdc Or Ac Rms
Continuity
Audible Indication: Less Than 100 Ohm
Response Time: 100Ms
Green Led Will Be On Continuously
Overload Protection: 500Vdc Or Ac Rms
Capacitance
Range: 200 Microf
Resolution: 0.1 Microf
Accuracy: ±(3% Rdg + 5 Dgts)
Overload Protection: 500Vdc Or Ac Rms
Dc Volts
Ranges: 200Mv, 2000Mv, 200V
Resolution: 0.1Mv
Accuracy: ±(0.5% Rdg + 1 Dgt)
Input Impedance: 560 K Ohms On V Inputs, 10 Mohms On Mv Input
Overload Protection: 600Vdc Or Ac Rms, 500Vdc/350Vac Rms 15 Sec On 200Mv Range
Transient Protection: 6Kv For 10 Micro Sec
Ac Volts (50Hz – 500Hz)
Ranges: 200Mv, 200V, 600V
Resolution: 0.1Mv
Accuracy: ±(1.2% Rdg + 3 Dgts) ±(2.0% Rdg + 5 Dgts) On 600V Range
Input Impedance: 560 K Ohm On V Input, 10 Mohm On Mv Input
Overload Protection: 600V Dc Or Ac Rms
Transient Protection: 6Kv For 10 Micro Sec
Resistance
Ranges: 200 Ohm, 200 K Ohm
Resolution: 0.1 Ohm
Accuracy: ±(1.0% Rdg + 4 Dgts)
Open Circuit Volts: 0.3Vdc Typical, (3.0Vdc On 200 Ohm Range)
Overload Protection: 500Vdc Or Ac Rms
Temperature
Range: -30 To 200°F (-34 To 93°C)
Resolution: 0.1°F/°C
Accuracy: ±1°F, 32 To 120°F (0 To 48°C), ±1% + 1.5°F, -4 To 200°F (-20 To 93°C), ±2% + 3°F, -30 To -4°F (-34 To -20°C).
Sensor Type: K-Type Thermocouple
Overload Protection: 60 Vdc Or 30 Vac Rms
Field °F Calibration
For Accuracies Of ±°F, Calibrate The Hs33 To A Known Temperature. A Glass Of Stabilized Ice Water Is Very Close To 32°F (0°C) And Is Usually Very Convenient But Any Known Temperature Can Be Used.