Overview
Immersion Type Controllers For Hydronic Heating Systems That Turn Off The Burner Whenever The Boiler Water Temperature Rises To The Setpoint. Vertical Mounting.
Features
- High Limit Aquastat Controller Has Adjustable Set Point.
- Models Available For Use With Immersion Wells Or For Direct Immersion If Faster Response Is Needed.
- A Factory-Set Stop Is Available On L4080 To Prevent Setting The Control At Too High A Temperature.
- Models Available With Second Limit Switch To Shut Off All Gas To The Burner.
- Liquid Fill In Sensing Element Expands As The Boiler Temperature Rises.
- At The Set Point Temperature, A Diaphragm-Actuated Snap Switch Breaks The Power Supply To The Burner Primary Control.
Product Specifications
- Application: Immersion Type Controllers For Hydronic Heating Systems That Turn Off The Burner Whenever The Boiler Water Temperature Rises To The Set Point.
- Insertion Depth: 3 In.
- Temperature Range (F): Maximum – 40 F Above Setpoint Or 265 F, Which Ever Is Lower.
- Includes: Siphon Loop
- Mounting: Mount Using 1/4 In. Npt Female Threads Or Surface Mount Through Base Of Case
- Electrical Ratings (Millivolt)
- 0.25 A @ 0.25 To 12 Vdc
- At Full Load – 8A @ 120 Vac , 4A @ 240 Vac
- At Locked Rotor – 48A @ 120 Vac , 24A @ 240 Vac
- Operating Temperature Range (F): 100 F To 200 F
- Differential Temperature (F): 8 F
- Switching Action: Breaks Contact On Temperature Rise To Set Point.
- Insulation Depth (In.): 1 1/2 In. To 3 In.