3/4″ Npt X 3/4″ Npt Intermittent Hot Surface Pilot Ignition Smartvalve Control With Standard Opening And 3.5″ Wc Pressure Regulator Setting
Includes: (2) 3/4″ X 1/2″ Reducer Bushings And An Lp Conversion Kit.
Features
- These Controls Communicate Directly With An Electronic Fan Timer (St9160 Electronic Fan Timer For Single Stage Applications; St9162 Electronic Fan Timer For Two-Stage Applications) In Typical Forced Warm Air Furnace Applications.
- They Also Interface With The 208907 Terminal Board, Providing Compatibility With Power Stealing Thermostats. Or, They Directly Interface With The Appropriate Power Supplies And A System Thermostat For Additional Appliance Applications.
- When Controlled Directly By A Thermostat, These Controls Do Not Provide A Postpurge Function, Because Power To The Control Is Removed When The Thermostat Call For Heat Ends.
- The Sv9541 And Sv9641 Systems Are Suitable For A Wide Range Of Fan-Assisted Combustion Gas-Fired Appliances Including Furnaces, Rooftop Furnaces, Boilers, Unit Heaters, Infrared Heaters, Water Heaters And Commercial Cooking Appliances.
- Flame Sense: Two Rod
- Type Of Gas: Natural
- Ignition System Type: Intermittent Hot Surface Pilot Ignition
- Ignition Sequence: Intermittent Pilot
- Ignition Source: Pilot
- Ignition Trials To Lockout: Continuous Retry
- Prepurge: 15 Seconds
- Body Pattern: Straight-Through
- Opening Characteristics (Standard, Step): Standard Opening
- Control Voltage (Thermostat Or Other Call For Heat): 24 Vac
- Ignition Trial Time (Sec): 90 Sec
- Electrical Ratings: 24 Vac
- Frequency: 60 Hz
- Frequency: 50 Hz
- Flame Failure Response Time (Sec): 1.6 Sec @ 3 Îœa
- Ambient Temperature Range (F): -40 F To +175 F
- Ambient Temperature Range (C): -40 C To +79 C
- Dimensions (In.): 3.2 In. Wide X 4.9 In. High X 4.1 In. Long
- Dimensions (Mm): 81 Mm Wide X 124 Mm High X 104 Mm Long
- Pressure Regulator Setting (Psi): 3.5 In. Wc
- Pressure Regulator Setting (Kpa): 0.87 Kpa
- Pressure Ratings (Psi): 1/2 Psi
- Pressure Ratings (Kpa): 3.5 Kpa
- Inlet/Outlet Size (In.): 3/4 In. Npt X 3/4 In. Npt.
- Maximum Capacity (Ft³/Hr): 415 Ft³/Hr
- Maximum Capacity (M³/Hr): 11.8 M³/Hr
- Minimum Capacity (Ft³/Hr): 30 Ft³/Hr
- Minimum Capacity (M³/Hr): 0.8 M³/Hr
- Maximum Capacity At 1 In. P.D. (Ft³/Hr): 300 Ft³/Hr
- Maximum Capacity At 1 In. P.D. (M³/Hr): 8.5 M³/Hr
- Pressure Tapping: 1/8 In. – Npt
- Mounting: 0 To 90 Degrees In Any Direction From The Upright Position Of The Gas Control Knob, Including Vertically.
- Pilot Gas Outlet: Yes
- Tradeline Value: Super Tradeline